Rising Medical Co., Ltd.



 
Ultrasound Scanner

12-lead Resting PC-ECG Electrocardiograph

Inquire now

12-lead Resting PC-ECG Electrocardiograph

Click to enlarge image

 Origin China
 Model Number CardioScape 1.0 & 3.0

Product Name: 12-lead Resting PC-ECG System
 

Model:

CardioScape PC-ECG 1.0 & 3.0

 

Version 1: CardioScape PC-ECG 1.0
Function (2 functions):

  • ECG: 12-lead resting PC-ECG with auto interpretation
  • VCG: Vector-cardiograph with auto interpretation

Version 2: CardioScape PC-ECG 3.0
Function (8 functions):

  • ECG: 12-lead resting PC-ECG with auto interpretation
  • VCG: Vector-cardiograph with auto interpretation
  • TVCG: Timed Vector-cardiograph
  • FCG: Frequency ECG (unique technique to detect ischemia and CAD)
  • HFECG: High Frequency ECG
  • SAECG(VLP): Signal Averaged ECG or Ventricular Late Potentials, time domain and 3-D frequency domain)
  • QTD: QT Dispersion with chroma map
  • HRV: Heart Rate Variability (time domain, 3-D frequency domain, Lorenz poincare plots
Hardware Features:            
  • High sampling rate of 1000Hz
  • Digital filter system
  • Applying anti-baseline-drift technology ensuring the stability of ECG baseline
  • Wilson and Frank hookup system
  • Meet the international standard of IEC60601-1
  • Easy operation and perfect printout
  • Diagnosis of coronary heart disease
  • Perfect time domain, frequency domain and non-linear HRV analysis
  • Perfect ECG database management system

Specification:   

  • Sample rate: 1000Hz, simultaneous 12 leads recording
  • Resolution:12bit
  • Power: 5.0V (DC)
  • Patient Insulation: 4000V AC
  • Defibrillation Protection: Built-in box
  • Digital resolution: 2μV
  • Frequency response: 0.05-250 Hz
  • Common mode rejection: >90dB
  • Input impedance: >10MΩ
  • Time constant: ≥3.2 s
  • Max electrode potential: ±300mV DC
  • Dynamic range: ±10mV
  • Isolate voltage: 4000V
  • Current leak: <10μA
  • Patient cable: standard 10-wire, 15-pin D connection
  • PC interface: USB


Related Keywords: ecg , ekg , pc ecg , pc ekg , electrocardiograph , holter , stress test